Small businesses
Lite 8 PoE
Connect a few devices and PoE consumers via gigabit. The number of ports and the shared power budget limit the expansion.
Ubiquiti UniFi switches for Swiss SMEs and campuses: PoE, multi-gigabit, fiber optic uplinks, VLANs, aggregation and stacking, clearly planned and supported.
A switch connects workstations, servers, access points and cameras to the rest of the network. In order for the connection to be suitable in everyday life, in addition to the number of ports, speed, PoE performance and uplinks also count. Irontec plans UniFi switching for small offices to multi-tier campus networks. We explain the differences between access switches, aggregation and WAN switches and coordinate hardware, cabling and operations for your location.
Choose the building blocks that suit your initial situation. We determine the scope and support together.
Record workstations, access points and cameras in a port list. Consider reserves for new devices and the required data rate.
PoE supplies suitable end devices via the network cable. We check the required standard and the common budget of all occupied ports.
Connect floors, servers and distributors with suitable uplinks. Port types, optics, cable length and remote stations must match.
Assign network areas for company devices, guests and cameras. Releases between areas are coordinated with routing and firewall.
Select the supported redundancy functions specifically. A stack of individual switches in a rack is not a logically managed switch stack.
Document port assignment and connections. Malfunctions, extensions and updates can be processed and tracked in a targeted manner.
From the compact PoE switch to stacked access switches and redundant aggregation.

Small businesses
Connect a few devices and PoE consumers via gigabit. The number of ports and the shared power budget limit the expansion.

Medium-sized companies
Combine Gigabit and 2.5 GbE devices, with fast SFP+ uplinks to the rest of the network. Plan PoE reserve for access points and cameras.

Large companies & campuses
ECS-48S-PoE as access level, ECS Aggregation as higher connection level. Maximum of four ECS-S switches per stack; Plan redundant connections separately.
The examples are planning recommendations, not fixed capacity limits or complete packages. CHF indicative pricing per device pictured; exact price on request. All models in the following comparison have their own detail pages.
View all UniFi products →A selection of important products for your project. Irontec tailors devices, setup and ongoing support to your needs.
Hardware guide prices in CHF, excluding VAT, shipping, any import taxes and setup. Product price status: September 15-16, 2026. Conversion: 1 EUR = CHF 0.9441 (ECB, September 15, 2026). Exact price on request. We will confirm availability and total price with your offer. Course source
The number of ports alone is not enough. Data rate, power budget and connections to the rest of the network must match.
| product | Lite 8 PoEUSW-Lite-8-POE-EU | Pro Max 16 PoEUSW-Pro-Max-16-PoE-EU |
|---|---|---|
| Area of application | Small installations with a few PoE devices | Growing offices with cameras and fast access points |
| Network ports | 8 × Gigabit, of which 4 × PoE+ | 12 × Gigabit PoE+, 4 × 2.5 GbE PoE++ |
| Fast uplinks | Via gigabit ports | 2 × 10G SFP+ |
| PoE budget | 52 W total | 180 W total |
| To be taken into account | Fanless; no 2.5-GbE ports | Rack mounting requires separate accessories |
| Guide price excluding VAT | CHF 112.16per device · exact price on request | CHF 406.72per device · exact price on request |
| Deliverability | Sold out from the manufacturer at the current price | On request |
| Find out more | Product details →Inquire about product ↗Manufacturer details ↗ | Product details →Inquire about product ↗Manufacturer details ↗ |
Access ports, aggregation and Internet handover fulfill different tasks. The components are planned as a coherent topology.
| product | Enterprise Campus 48S PoEECS-48S-PoE-EU | Enterprise Campus AggregationECS-Aggregation-EU | WAN SwitchUSW-WAN-EU | UniFi 5G MaxU5G-Max |
|---|---|---|---|---|
| Area of application | Large access networks | Aggregation for large locations | Internet handover to a gateway pair | Additional internet route |
| task | 48 PoE ports: 16 × 10 GbE and 32 × 2.5 GbE | Bundling connections between the access level and gateways | 3 × 10G SFP+: Internet connection and two gateways | 5G backup via UniFi LAN |
| Availability | Up to four ECS-S devices per stack; two power supplies | MC-LAG as a pair; redundant power supplies | Two AC inputs; one switch per provider | A single modem is not a redundant pair |
| Planning | 950 W PoE budget in redundant 230-V operation | Coordinate optics, uplinks and port assignment | Check provider handover and gateway compatibility | Test reception, SIM/eSIM, data volume and failover |
| Guide price excluding VAT | CHF 4'077.38per device · exact price on request | CHF 4'077.38per device · exact price on request | CHF 254.91per device · exact price on request | CHF 406.72per device · exact price on request |
| Deliverability | On request | On request | On request | On request |
| Find out more | Product details →Inquire about product ↗Manufacturer details ↗ | Product details →Inquire about product ↗Manufacturer details ↗ | Product details →Inquire about product ↗Manufacturer details ↗ | Product details →Inquire about product ↗Manufacturer details ↗ |
Wi-Fi coverage and performance depend on building, device and configuration. EU devices may require a suitable Swiss connection cable. Optional accessories, data carriers and additional paid services are only included if expressly stated.
Example situations – we tailor the specific implementation to your requirements.
A compact UniFi switch connects workstations and selected devices. We check whether the gigabit connection and power budget match the actual needs.
Fast access points and cameras require different ports and power reserves. We create an occupancy plan and coordinate uplinks with the next network level.
Access switches are connected via planned aggregation. Suitable stacks, replacement paths and separate power supplies are set up and tested together.
Eight free sockets are of little help if the type of device required requires a faster connection or a different PoE standard. We differentiate between wired workstations, access points, cameras and servers. Example: In the office, gigabit ports may be sufficient for individual devices, while fast access points require suitable 2.5 or 10 GbE ports. In addition, uplinks and reserves for expansions are planned.
PoE delivers data and power via one cable. Two pieces of information are crucial: the supported performance on the individual port and the total available PoE budget. Planning example: Four consumers with 25 W each result in a total of 100 W before additional reserve. A switch with a total budget of 52 W is not enough for this, even if all devices can be physically connected. We examine the performance requirements of each device type and the intended power supply operation.
An uplink connects a switch to the next network level. If many fast connections share a slow uplink, a bottleneck can arise there. SFP-based connectors require appropriate modules or direct connection cables; Form factor, speed and remote device must be compatible. We plan building connections and server connections based on the required range and expected data traffic.
Access switches provide the connections for end devices. Aggregation bundles connections from multiple distributors or floors. A WAN switch has its own role at the Internet gateway, for example to pass on a provider connection to a gateway pair. These devices are not interchangeable sizes of the same product. The comparison shows their respective uses, and the network overview combines them into complete equipment suggestions.
LACP combines compatible connections into one logical connection; This does not automatically make a single data stream faster by the number of cables. For supported ECS-S switches, stacking connects multiple devices into a jointly managed unit. ECS Aggregation can provide redundant connections as a MC-LAG pair. We select the function according to remote stations and failure requirements. Current campus planning uses three stacks of four for twelve access switches.
Two power supplies only help in the intended operating mode and with a suitable power supply. For the ECS-48S-PoE, Ubiquiti states a PoE budget of 950 W for 200-240 V in redundant operation; Operating both power supplies together has a different budget. We plan reserves based on the desired failure event. Acceptance includes separate tests for switch, uplink and current path – with the agreed expectations in each case.
We record the required ports, data rates and PoE devices. This forms the basis for a port plan, uplink design and equipment selection. VLAN assignments, links between distribution points and planned backup paths are documented. Redundancy is checked for the specific combination.
You receive an agreed scope covering hardware, setup and optional support. Product pages show indicative CHF prices; the final quotation takes your site into account.
Discuss your UniFi project ↗We arrange analysis, implementation and ongoing support based on your location. You will receive a comprehensible offer and the agreed documentation.
Include devices, cabling and performance requirements.
Set switches, port assignment, VLANs and connections.
Accept configuration and test data and power supply.
Document port plan, device overview and agreed failure tests.
The Lite 8 PoE can fit few Gigabit and PoE devices. If faster ports or more PoE performance are required, other equipment may be considered. The decisive factors are the connected devices and the planned reserve.
The ECS-S planning provided here uses a maximum of four devices per stack. Twelve access switches are therefore planned as three stacks of four. The model, software version and cabling must support the required functions.
No. Shared management in UniFi Network does not automatically mean stacking. The stack functions described refer to suitable ECS-S devices. Pro Max switches in our office examples are managed individually.
A VLAN initially separates logical network areas. The routing, firewall and, if necessary, access control rules determine which communication is permitted between them. We plan and test these rules together.
The CHF guide prices shown refer to the hardware described. Required optics, cabling, accessories, installation and support will be shown separately in your offer unless expressly included. The exact price is available upon request.

Ubiquiti UniFi WLAN for offices, SMEs and campuses: radio planning, WiFi 7 access points, guest access and roaming. Irontec plans, installs and maintains your solution.
Discover solution
Ubiquiti UniFi Complete solutions for Swiss companies: Plan WLAN, switching and firewalls together – from small offices to redundant campuses.
Discover solution
Ubiquiti UniFi switches for Swiss SMEs and campuses: PoE, multi-gigabit, fiber optic uplinks, VLANs, aggregation and stacking, clearly planned and supported.
Discover solution
Ubiquiti UniFi firewalls, UDM and cloud gateways for Swiss companies. Compare models, plan VPN and failover – with Irontec.
Discover solutionCompanies and organisations using Ubiquiti UniFi with Irontec. The labels indicate which customers also use UniFi Protect.






A selection from the areas of web, collaboration and digital customer acquisition. Discover the implementation in the published project reports.
Financial Services
Website and collaboration connected.
Irontec relaunched the website and created a digital sales channel. The project also included Microsoft 365 with shared files and mailboxes, training and a peoplefone VoIP solution.
Read project reportEngineering
A new appearance for complex projects.
The project report describes the website relaunch with workshops, responsive implementation and search engine optimization. An individually developed reference function enables PDF creation from selected projects.
Read project reportAdvice
From the foundation to the digital workplace.
The website, logo and corporate identity were created together with a Microsoft-365 environment. Email, shared file storage and training supported collaboration across different work locations.
Read project reportTraining
Be found online. Simply register.
Irontec implemented a responsive website with contact and course registration. In addition, target groups and search terms were developed and four Google Ads campaigns were set up and optimized.
Read project reportThe project reports document the scope of services at that time.
Tell us what you're up to. We think along.